Steam tables fail for one reason more than all the others combined: they get run dry. Somebody turns the wells on before the water goes in, or the water boils away during a long banquet, and the element cooks itself. Around the lake, where kitchens run events and buffets in bursts rather than every day, that happens more often than in a restaurant with a daily routine. We service clubs, marinas, event kitchens and restaurants across Lago Vista, Point Venture and Jonestown. Commercial diagnostic is 149 dollars and goes toward the repair. EPA certified and insured.

Common causes. A burned out element, an infinite switch or thermostat, a failed contactor, or on gas units an igniter or valve problem. On a multi-well table each well usually has its own element and control, so one dead well tells you nothing about the others.
What we do. We test each well circuit separately, measuring element resistance and switch output rather than assuming a shared fault.
Common causes. Dry firing. A wet well element is cooled by the water and fails quickly without it. Long events, a slow leak at a drain valve, or starting the table before filling all do it.
What we do. We replace the element and check why the water went: a leaking drain valve, a cracked well, or simply no low water protection on that model. Replacing the element without finding the leak means doing it again next banquet.
Common causes. A weak element in one well, a thermostat out of calibration, different water levels between wells, or scale coating one element so it transfers heat poorly.
What we do. We measure actual water and product temperature in each well and compare, then test the element and control for the one that is off.
Common causes. Hard water plus evaporation. Every gallon that boils off leaves its minerals behind, so a steam table concentrates scale faster than almost anything else in the kitchen.
What we do. We descale the wells and elements properly and tell you a realistic cleaning interval for this water, because scale on an element shortens its life and slows heat up.
Common causes. A drifted thermostat, a sensor reading well water rather than product, or pans that do not sit properly so steam escapes around them.
What we do. We measure product temperature in the pans, which is the number an inspector cares about, and check pan fit before changing controls.
Common causes. A drain valve that no longer seats, a corroded or cracked well, or a loose fill or drain fitting. A slow drain leak is also the usual reason a well runs dry mid service.
What we do. We rebuild or replace the valve and fittings. A cracked well is a replacement and we will say so rather than chasing it.
Common causes. Infinite switches worn from daily use, a control damaged by steam and heat over the years, or corroded terminals in a wet environment.
What we do. We test the switch and wiring. Terminals corroded by years of steam are a common and inexpensive find.
Common causes. Scaled elements, a partly failed element still drawing some current, low voltage, or simply filling with cold water too late. On gas units it points at burner input.
What we do. We measure current draw per well and time the heat up, which separates a failing element from a late start.
Electric and gas steam tables, wet and dry well units, drop-in and freestanding, hot holding cabinets and carving stations. Common brands include Vulcan, Wells, Duke, APW Wyott, Hatco, Star and Alto-Shaam.
Event and club kitchens here often pull a steam table out of storage for a weekend. Checked before the event it is a small job, discovered during it, it is a problem with guests in the room.
Commercial diagnostic is 149 dollars and is credited toward the repair when you approve the work. The final price depends on the part, how many wells are affected, and how much descaling the unit needs.
Work carries a 3 month labor warranty and installed parts carry a 1 year manufacturer defect warranty. We quote before the work starts.
Lago Vista including the marina and club areas, Point Venture, Jonestown, and out along FM 1431 toward Leander and Cedar Park. We also cover Lakeway and Bee Cave on the south shore.
Usually the well is losing water. Check the drain valve for a slow leak, fill before switching on, and watch the level through long events. The element is the symptom, not the cause.
Yes. In a wet well the water carries the heat away. Without it the element temperature climbs very quickly, and the damage is done long before anybody notices.
Often. Everything that boils off leaves minerals behind, so a steam table scales faster than other equipment here. We will tell you what yours needs after looking at the elements.
Same-day wherever we can. If you have an event coming, call before it rather than during it and we will check the unit while it is still a small job.
Call or book online and tell us the brand, how many wells are affected and whether it is gas or electric. Commercial diagnostic 149 dollars, applied toward the repair.