A fryer that is twenty five degrees off does not look broken, it just quietly costs you oil, product and consistency all day. Most of the fryer calls in Pflugerville come from kitchens that run one or two pots hard through a lunch rush, and the complaint is almost always recovery time rather than a fryer that is actually dead.

On a gas fryer this is usually the thermostat, the gas valve or burners that need cleaning. On electric it is an element or a contactor. Before any of that, the actual oil temperature gets measured against what the dial says, because a fryer that is simply out of calibration needs adjusting rather than parts.
A thermostat that is not cutting out, a probe reading low, or a control that has lost calibration. Overshoot is harder on oil than running cool: it accelerates breakdown, so the oil costs go up before anyone notices the food is darker than it should be.
Thermocouple, pilot assembly, the gas valve, or a flame sensor reading too little current. A pilot that lights and drops when the knob is released is the classic thermocouple pattern. We measure the sensor rather than guessing, because replacing a valve for what turns out to be a dirty pilot is an expensive mistake.
A high limit does not trip for no reason. Low oil level, carbon on the probe, a failed thermostat letting it run away, or a high limit that is genuinely weak. This is the one that gets investigated rather than reset, because the limit is the safety device standing between hot oil and a fire.
Heavy carbon on the tubes or elements, a gas supply that is not sufficient when several pieces of equipment fire together, or burners that need cleaning. In a small Pflugerville kitchen where the fryer, the griddle and the range all come on at once, it is sometimes the supply rather than the fryer.
Usually the drain valve, the valve packing, or a weld seam in the pot. Oil on a kitchen floor is both a slip hazard and a fire hazard, and a weeping drain valve gets worse rather than better. Pot seams are where we tell you honestly whether a repair is worth doing.
Filter pump, the paper or pad fitted wrong, a clogged suction tube, or the O-rings on the connection. Crews often work around a filtration system that has stopped, and then the oil goes longer between changes, which costs more than the repair would have.
Propane regulators, a tank running low, and ambient conditions all change what the burner sees, so a trailer fryer that is fine in the morning can be slow by the afternoon. It is worth separating the fryer from the gas supply before ordering anything for it.
Open pot and tube-fired gas fryers, electric fryers, units with built-in filtration, donut and specialty fryers, countertop fryers and fryer batteries. Common brands include Frymaster, Pitco, Henny Penny, Vulcan, Imperial, Dean, Ultrafryer and Star.
Gas work is done to manufacturer specification, and we check that a fryer converted between natural gas and propane is set up correctly rather than assuming it is.
Restaurants and taquerias along Pecan Street and FM 685, fast casual at Stone Hill Town Center, bars and event venues, school and daycare kitchens, convenience stores with hot food programs, and food trailers.
The commercial diagnostic is one hundred forty nine dollars and it is credited toward the repair once the work is approved. A fryer down in the middle of service is urgent and gets treated that way.
Ten degrees is noticeable in product quality. Twenty five is costing you oil life and consistency every day. Calibration is a cheap service call compared with what a drifting fryer costs over a month.
Not more than once. A high limit that trips repeatedly means something upstream is failing and the limit is the only thing stopping it. That is a same-day call rather than something to work around.
Weekly in most kitchens, more often with heavily breaded product. Carbon on the tubes or elements is the single biggest cause of slow recovery, and a boil-out schedule prevents more service calls than any other habit.
Yes. Tell us when you book where the trailer will be parked and whether it will have power and propane connected, since both have to be live to test under load.
Usually yes. Thermostats, valves, thermocouples, elements, contactors and drain valves are all serviceable parts and a stainless pot lasts a long time. A cracked or weeping pot is where we will tell you to price a replacement instead.
Tell us the brand, whether it is gas or electric, and what the oil is actually reading against the dial, and we can usually narrow it down before we arrive. Call (737) 388-3867. The one hundred forty nine dollar commercial diagnostic is credited toward the repair.