When the cookline is down or the kitchen is full of smoke, service stops. We repair commercial range tops and the exhaust hood above them for restaurants, cafeterias, schools and church kitchens in Leander — burners, valves, pilots and controls below, fans, belts, motors and lights above. The $149 commercial diagnostic is credited toward the repair, and you get a firm price before anything is replaced.

On a standing-pilot range that is the thermocouple or the pilot itself, not the valve body. The pilot flame has to wrap the thermocouple tip properly to keep enough millivolts on the safety magnet; a pilot that has drifted, or an orifice partly blocked with grease and dust from the line, drops the signal and the valve closes. We measure the thermocouple output under load rather than guess, because a weak thermocouple and a weak pilot look identical from across the kitchen. On electronic-ignition units the same symptom points at the flame sensor or the ignition module, and that is a different measurement again.
Those are two different faults with one common cause behind them. No light at all is usually gas supply, the valve, or the igniter circuit. A yellow, lifting or sooty flame is air and pressure: a blocked orifice, an air shutter closed by cleaning, or manifold pressure that is wrong for the gas the building actually has. Natural gas and propane need different orifices, and a range converted once years ago and never checked is a common find. We take manifold pressure at the tap and compare it against the rating plate before touching anything, because every other adjustment is meaningless until that figure is right.
On a multi-burner top this is almost always distribution, not a dead part. If the manifold pressure drops when several burners run together, the gas line or regulator is undersized or partly obstructed, and the burners at the far end starve. We light the whole top and watch what pressure does under full load. A single burner that is weak while everything else is fine is a local orifice or valve problem and is a far cheaper job.
Capture failure is usually one of three things, and they are cheap to tell apart. Loaded filters, a slipping or stretched fan belt, or a makeup air problem. Grease-saturated baffles choke airflow long before anyone notices visually. A belt-driven rooftop fan loses most of its pull on a belt that still looks intact. And if the building cannot supply replacement air, the hood simply cannot move what it is rated for — NFPA 96 requires makeup air sized so the building does not go more than 0.02 inches water column negative, and a kitchen past that will not capture no matter what fan is on the roof.
That pair of symptoms together is the signature of a kitchen running too negative, and it is worth treating seriously rather than relighting pilots every morning. When exhaust outruns makeup air, the building pulls air in through whatever opening it can find, including the flues of gas appliances. Reversed flue gas puts combustion products into the kitchen. We check the makeup air unit, its interlock with the hood, and whether anything was switched off or belt-stripped before deciding that the hood itself is at fault.
Rooftop exhaust fans fail in a predictable order: belt, bearings, wheel. A wheel loaded unevenly with grease goes out of balance and chews bearings within months, which is why fan condition and cleaning schedule are connected. We check amperage against the motor nameplate, the belt tension and alignment, and the shaft play by hand. A motor tripping its overload on a hot afternoon with clean bearings is usually a wheel problem or a supply voltage problem, not a motor that needs replacing.
Baffle filters only work installed the right way round and seated so grease drains into the collection track. Filters put back upside down after a wash, filters that are bent, and missing end caps all let grease run down the face of the hood instead. NFPA 96 requires filters that are broken, distorted or missing components to be replaced rather than kept in service, and it requires that the system never run with filters taken out at all. If the drip is coming from the duct seam rather than the filters, that is a cleaning and duct question and needs a certified exhaust cleaning contractor.
The light circuit on most hoods runs through the same control panel as the fan, so a dead light with a working fan is a lamp, a socket or the switch, and a dead everything is the supply or the panel. On hoods tied into a fire suppression system there is also a shunt trip and a micro-switch in the circuit, and those have to be checked and left exactly as they were found. We do the electrical repair on the hood itself; anything inside the suppression system is a licensed fire protection contractor's work and we will say so rather than open it.
We service commercial gas and electric range tops, hot tops and French tops, countertop and heavy-duty ranges, griddles and charbroilers on the same line, and the exhaust hood above them — canopy and low-proximity hoods, wall-mount and island, direct-drive and belt-driven exhaust fans, and makeup air units tied to the hood.
Brands we repair in Leander: Vulcan, Garland, Southbend, Imperial, Montague, Star, Atosa, Cooking Performance Group, American Range, Captive-Aire, Greenheck, Larkin and Avantco.
What we do not do, and will tell you honestly on the phone: certified NFPA 96 exhaust cleaning to bare metal, and anything inside the fire suppression system. Both of those are licensed specialist work, and we would rather hand you a name than open a panel we should not.
The commercial diagnostic is $149, credited toward the repair when you approve it. After the diagnosis you get a written estimate covering parts and labor, and nothing is replaced before you approve it. Cooktop repairs are usually parts-light and labor-light; hood work depends on whether the fault is at the hood, on the roof, or in the makeup air system, because roof access changes the job.
Gas work always finishes with a leak check on anything we opened, and we leave the manifold pressure reading with you in writing.
Our commercial cookline calls in Leander cluster along US-183 and Hero Way, around the Leander Station area, and the restaurant space off Ronald Reagan and Crystal Falls Parkway. School and church kitchens out toward Bryson and Travisso are on the same run. Being based in Leander means roof access and a return trip are not a second-day problem.
Not the full NFPA 96 cleaning — that has to be done to bare metal by a trained and certified crew, and it covers the hood, the whole duct run and the rooftop fan. We repair the equipment: fans, motors, belts, controls, lights and the cooking appliances underneath. Day-to-day filter cleaning is the kitchen's own job and makes more difference than most operators expect.
NFPA 96 does not put a number on routine filter cleaning, but it does require that the system never run with the filters out, and that damaged or distorted filters be replaced. In practice a high-volume line wants them washed daily and a lighter one weekly. Loaded filters are the most common reason a hood stops capturing.
It matters a great deal, and it is one of the first things we check. Orifices and regulator settings are specific to the gas type, and a conversion that was done partly, or done and then undone when the equipment moved, shows up as yellow flames, soot and burners that will not reach temperature. The rating plate tells us what the unit should be set to.
Yes, for repair work: belts, bearings, motors, wiring and controls. If what the fan actually needs is grease removal, we will tell you that instead of charging you to replace a wheel that will load up again in a month.
Usually same-day or next morning. Call (737) 388-3867 and say whether you are down completely or running limited — a cookline that cannot serve gets priority over a hood light.
Tell us whether the problem is at the cooktop or the hood, whether the range is natural gas or propane, and what you are seeing. That is normally enough for us to arrive with the right parts on the van.